Energy Management SolutionsWHY bother about Energy Management when facilities are running smoothly?
  • Typically, in any building facility, air conditioning contributes to 30% to 45% of the total energy consumption.
  • High cost of energy. This will continue to rise due to increasing gap between supply and demand.
  • Concern for the Environment. Every unit of energy generated adds emissions to the atmosphere.
  • Government legislation.
   WHO is the right choice for carrying out an Energy Management exercise for your facility?One who has:
  • Knowledge of Energy Saving Products.
  • Application Engineering Capabilities.
  • Appropriate Instruments and Intellect.
  • Guaranteed Energy Saving and Return on Investment.
   WHY UTSAV, UTSAV has:
  • Hands-on experience in HVAC systems.
  • Knowledge of plant operations, maintenance and trouble shooting skills.
  • Wide range of energy saving products.
  • Large complement of intellectual capital.
  • Utsav is the right choice for giving guaranteed energy saving solutions with attractive payback.
   OUR Energy Partners
  • VFD (Variable Frequency Drives) - Nelco, Siemens
  • Energy Efficient Refrigeration Technologies - Hi-Freeze (Australia)
  • BMS (Building Management Systems) - Siemens
  • Ozone Injection Systems - Ruks, Canada
   Our Approach:
  • Evaluate Plant's performance and compare with Design.
  • Carry out detailed Energy Audit using appropriate instruments such as Analyzers and Compute through Software.
  • Submit a detailed report on plant performance, with suggestion for improvement and energy reduction.
  • Carry out the modifications and repeat the audit to demonstrate improvement.
   Methodology For Energy AuditAudit is conducted with patented Analyser, which measures following:
  1. Temperature;
    • Discharge line of compressor.
    • Liquid refrigerant.
    • Suction line of compressor.
    • Incoming cold transfer medium.
    • Outgoing heat transfer medium.
  2. Pressure;
    • High pressure compressor.
    • Low pressure compressor.
  3. Electrical power input to the compressor;
  4. Heating and cooling capacity;
   AnalyserBased on the above input measurement following parameters are calculated and displayed:
  • Evaporating temperature.
  • Condensing temperature.
  • Discharge gas temperature.
  • Superheat of the suction gas.
  • Sub-cooling of liquid refrigerant.
  • Entering temperature to evaporator.
  • Leaving temperature after condenser.
  • Coefficient of performance cooling cycle.
  • Efficiency of compressor.
   Energy saving products:We have formed strategic partnerships with manufacturers for the following energy saving products;
   Energy Management:Products offered by UTSAV AC&REnergy Efficient Refrigeration Technologies - Hi-Freeze (Australia)

Copyright 2005 utsavgroup.com                                                             Best viewed on IE 5.0 and above & Netscape 6.0 and above